Sign In | Join Free | My tjskl.org.cn
China Beijing Tianyihongda Science & Technology Development Co., LTD logo
Beijing Tianyihongda Science & Technology Development Co., LTD
Sincerity Is Fundamental, Clients Is The First. Strict Quality Control, Earnest Service Supply.
Site Member

7 Years

Home > Fault Path Indicator >

Anti Rust Precision Approach Path Indicator For Fault Path 12W / 10V Solar Panel Power

Beijing Tianyihongda Science & Technology Development Co., LTD
Contact Now

Anti Rust Precision Approach Path Indicator For Fault Path 12W / 10V Solar Panel Power

  • 1
  • 2

Brand Name : TYHD

Model Number : TYHD-AI9

Certification : type test report

Place of Origin : Beijing;China

MOQ : 1 set

Price : Negotiation

Payment Terms : L/C, T/T, Western Union

Supply Ability : 3000 sets/month

Delivery Time : whthin 3-5 days

Packaging Details : standard export Package

Dimension of repeater station : H×W×T=388mm×366mm×368mm

Overall power consumption : <0.4W

Work time in rainy weather : ≥10 days

Power of solar panel : 12W/10V

Contact Now

Safety criterion

Welcome to use remote transmission unit manufactured by us. Each remote terminal uint has already experienced the complete assembly, test and inspection, also the careful check and adjustment before delivery, which has been in good condition when transport. When received, the repeater station shall be carefully checked for damage during transport, and in case of any problem, the carrier shall be reported immediately in written.

The package shall be carefully handled to avoid the damage and impact, the water shall be prevented during transport, and the corrosive materials cannot be transported in the same truck box as the package absolutely. If the equipment needs to be stored for a very long time before installation, it shall be in the clean place with good ventilation, the corrosive gas shall not be contained in the air, and it shall be stored with caution to avoid damage.

Device description

Remote terminal uint is the data acquisition and communications forwarding device for power distribution network load monitoring, fault detection and positioning system, which can be set as the practical distribution terminal device of two remote (remote signaling, telemetry) functions in the distribution automation system via terminal parameter configuration, which can also be set as the traditional distribution terminal device of remote fault positioning system.

The fault indicator for overhead distribution lines is used indicating of phase-to-phase and phase-to-earth faults by determining short circuit, over-current and power features to detect faults and provide a local light indication. In addition, the indicator also has current measurement and wireless data communication capabilities, by sending the fault signal to FTU,in order to comply the function of the remote communication and the remote monitoring, to help operators to find the point of failure quickly and shorten the outage time and improve reliability.

Main features and Functions

main features

functions

GSM or GPRS forwarding

Wireless receiving

Remote upgrade

Solar power supply

Work mode setting

Convenient maintenance


Event recording

Principle of Fault Indicator

The fault indicator installed on the overhead lines, which clipped on each phase so that to detect current and Voltage signal in this phase using itself clipped line structure. After the indicator is installed, the line current has been measured . The lineman simple follows the flashing fault indicators all the way to the first non-flashing fault indicator, thereby identify the fault location.The terminal device receives the fault information can further upload,

Introduction of device components

Anti Rust Precision Approach Path Indicator For Fault Path 12W / 10V Solar Panel Power

Preparation of debugging tools

Computer, a set of substation interface software, a set of overhead line maintenance software, RS232 serial port line, universal meter, cross screwdriver, nipper pliers, and one indicator with fault information.

Anti Rust Precision Approach Path Indicator For Fault Path 12W / 10V Solar Panel Power


Product Tags:

power supply failure indicator

      

precision approach path indicator

      
Quality Anti Rust Precision Approach Path Indicator For Fault Path 12W / 10V Solar Panel Power for sale

Anti Rust Precision Approach Path Indicator For Fault Path 12W / 10V Solar Panel Power Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Tianyihongda Science & Technology Development Co., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)